Error Code E gF
Defect of flow meter or lack of water supply — malfunction of flow meter. Check connection of flow meter and water supply.
Moderate
Address soon - your appliance may not work properly
Also displayed as: E gF
How to Fix
- 1
Step 1: Check flow sensor connector in the machine room for loose or damaged connection.
- 2
Step 2: Measure flow sensor resistance: Red wire to Black wire. Expected: 4 ~ 30 kΩ. If outside this range, replace flow sensor.
- 3
Step 3: Check water supply — verify saddle valve is fully open and water pressure is adequate.
- 4
Step 4: Check water filter condition. Replace if older than 6 months or if indicator is illuminated.
- 5
Step 5: Check water line for kinks or blockage.
- 6
Step 6: If flow sensor resistance is correct and water supply is adequate, replace Main PCB.
- 7
Step 7: If water pressure is low (less than 20 psi), advise customer to contact plumber.
This Error Applies To
LG LRYXC2606 Series Refrigerators
Related Error Codes
Defect of freezer craft ice maker sensor — short-circuit or disconnection of craft ice maker sensor
Defect of Mini Cubed ice maker kit — malfunction of Mini Cubed ice maker motor
Defect of refrigerator sensor — short-circuit or disconnection of refrigerator sensor
Defect of freezer sensor — short-circuit or disconnection of freezer sensor
Defrosting failure — defrost sensor does not reach 40°F (5°C) within 80 minutes after defrost starts. Causes: disconnected thermal fuse, defective defrost heater, defective heater relay, drain tube blockage.
Defect of BLDC fan motor for freezer — no feedback signal from fan motor for more than 65 seconds
Defect of BLDC fan motor for ice compartment — no feedback signal from fan motor for more than 65 seconds. Causes: defect of BLDC motor connection, Drive IC, or TR.
Defect of BLDC fan motor for machine room — no feedback signal from condenser fan motor for more than 65 seconds